Browse all practice questions for the Oxygen Therapy Devices Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Oxygen Therapy Devices Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • What is a true statement about a simple oxygen mask?
  • Which statement about reservoir cannulas is true?
  • Which mask is described as having an innovative open mask design?
  • Which is a pro of using a partial rebreathing mask compared with a simple mask?
  • Which color-coded nozzle corresponds to 2 LPM on a venti mask?
  • What length is typical for nasal catheter tubing?
  • Which statement is true about nasal cannula usage regarding sterilization?
  • Which color corresponds to 12 LPM on a venti mask?
  • Which statement correctly describes entrainment effects across venti mask/LVN and HFNC as oxygen concentration increases?
  • Which device allows very precise, stable FiO2 by varying the port size?
  • Which feature helps prevent CO2 rebreathing in the OxyMask?
  • Which statement about FiO2 with OxyMask is true?
  • Which PaO2 range corresponds to moderate hypoxemia?
  • Humidification with high-flow devices is not provided through which interface?
  • Venturi mask ports include which features?
  • Which statement about the face tent is true?
  • Which color corresponds to 4 LPM on a venti mask?
  • Which devices are considered reservoir systems?
  • What happens to FiO2 in low flow oxygen devices when inspiratory volume increases?
  • High-flow devices are typically used in which scenario?
  • What is the typical flow range for a nasal catheter?
  • Which statement best describes nasal cannula usage?
  • Oxygen therapy aims to prevent or minimize what aspect of the body's response to hypoxemia?
  • What is the minimum flow for a simple oxygen mask?
  • Which feature helps stabilize a nasal cannula on the head?
  • Low-flow oxygen delivery humidification is typically described as:
  • What is the flow range for the OxyMask?
  • Which statement best describes the reason for using higher flow with a simple mask?
  • Which is a disadvantage of using a nasal catheter for oxygen delivery?
  • What is the approximate FiO2 with nasal prongs at 2 liters per minute?
  • Why does a simple oxygen mask require a minimum flow of at least 5 L/min?
  • What is the minimum flow requirement to keep the reservoir bag inflated for partial rebreathing or non-rebreathing masks?
  • Which statement correctly describes nasal catheter placement?
  • Which statement best describes a compensatory response to hypoxemia?
  • The entrainment port size and the amount of air entrainment are...
  • Jet nozzle size in entrainment systems can be fixed or interchangeable.
  • In a partial rebreathing mask, approximately what fraction of the exhaled gas fills the reservoir during exhalation?
  • What is the maximum flow for the AIRVO2 system?
  • What is the approximate FiO2 with nasal prongs at 4 liters per minute?
  • What is the typical flow rate for a transtracheal catheter?
  • In a large volume nebulizer, which adjustment controls the FiO2 by changing the entrainment window?
  • Which is another goal of oxygen therapy besides correcting acute hypoxemia?
  • What is the primary function of reservoir systems in oxygen therapy?
  • In an entrainment system, increasing the amount of entrainment would most likely cause FiO2 to:
  • Why do transtracheal catheters require lower oxygen flows than nasal prongs?
  • At 7–8 L/min, what approximate FiO2 does a simple mask provide?
  • Why must the entrainment port remain open on a venti mask?
  • Which patient best fits the use of a non-rebreather mask?
  • What is the minimum recommended flow for a large-volume nebulizer circuit, typically expressed in liters per minute?
  • Which features characterize the oxyhood?
  • At 9–10 L/min, what approximate FiO2 does a simple mask provide?
  • What gases are used in high-flow devices to achieve a precise FiO2?
  • Which devices are examples of high flow nasal cannula devices?
  • Venti mask ports are designed with which features?
  • Venti mask FiO2 at 4 LPM is which value?
  • Which range best describes the maximum FiO2 achievable with a partial rebreathing mask at typical flow rates?
  • The Venti mask uses which principle to mix entrained air with oxygen?
  • How is adequate flow in a T-piece determined?
  • Aerosol entrainment collar serves what purpose?
  • What is the approximate FiO2 at 6 liters per minute?
  • What is a limitation of partial rebreathing masks at typical flow rates?
  • What is the equipment end of a nasal cannula?
  • Nasal and pendant reservoir cannulas conserve O2 at low flow by what percentage?
  • Which device is characterized as a high-flow oxygen delivery system?
  • What FiO2 range can HFNC provide?
  • What is the minimum flow rate required for partial rebreathing and non-rebreathing masks to keep the reservoir bag inflated?
  • Which tubing is used to deliver humidified oxygen to a face tent?
  • The Misty Ox nebulizer delivers what FiO2 range, and for what type of patients is it intended?
  • What are the three basic categories of oxygen therapy devices?
  • LVN is used for patients whose upper airways have been bypassed, such as with which devices?
  • In what setting are nasal and pendant reservoir cannulas used?
  • The amount of air entrainment depends on which factors?
  • Which of the following lengths are standard for nasal cannula tubing?
  • What is a disadvantage of pendant reservoir cannula?
  • Which therapy is used to treat croup?
  • In a T-piece oxygen delivery setup, where is the T-piece typically attached?
  • What are the primary types of large-volume nebulizers used clinically?
  • Where should the end of a nasal catheter be located for proper oxygen delivery?
  • In low-flow oxygen delivery, the total flow is typically described as which?
  • High flow systems are characterized by?
  • What best describes a high flow nasal cannula system?
  • In high-flow nasal cannula (HFNC), as oxygen concentration increases, what happens to flow?
  • What is the length of the nasal cannula tips?
  • Which device is an air entrainment mask?
  • Which statement best describes low flow oxygen devices?
  • Which statement best describes LVN ports?
  • The Venti mask operates on which principle?
  • Which statement best describes high flow oxygen devices?
  • What factors determine the actual FiO2 delivered by an oxygen delivery device?
  • What is the average capacity of the anatomical reservoir in an adult?
  • HAFOE stands for?
  • The OxyMask delivers FiO2 in what range?
  • What is the purpose of an oxygen tubing connector?
  • What happens to room air during NRB use?
  • Velocity of source gas and entrainment relationship?
  • Which factor affects oxygen delivery with high-flow devices?
  • Which statement about transtracheal catheters compared to nasal prongs is true?
  • In an entrainment nebulizer setup, which component connects to the flow meter via DISS then supplies gas to the aerosol mask or face piece?
  • High-flow devices total flow can reach up to how many liters per minute?
  • What is the FiO2 at 5 liters per minute with nasal prongs?
  • Connectors in ventilatory circuits are used to do what?
  • How often should a nasal catheter be switched from nare to nare to prevent irritation?
  • What FiO2 range can a nasal catheter deliver?
  • FiO2 and entrainment relationship?
  • What is the directional flow feature of the OxyMask?
  • In low-flow oxygen delivery systems, which factor most affects the actual delivered oxygen concentration?
  • What is the FiO2 at 6 liters per minute with nasal prongs?
  • What is the approximate FiO2 with nasal prongs at 3 liters per minute?
  • What determines the oxygen concentration on a Venturi mask?
  • Which statement about high-flow devices' total flow is correct?
  • Which statement describes the relationship between flow and FiO2 for nasal prongs?
  • Transtracheal catheter FiO2 range?
  • How is temperature maintained in an LVN system?
  • During inhalation on an NRB, which valve is open to allow uptake from the bag?
  • Which factor directly determines the delivered oxygen concentration with nasal prongs?
  • What is the main difference between a nasal reservoir cannula and a pendant reservoir cannula?
  • Inhalation with a non-rebreather mask, which valve configuration is correct?
  • Which statement best describes the nasal cannula tip configuration?
  • Which of the following is NOT an indication for transtracheal catheter?
  • Can the exact FiO2 be determined with a low flow device?
  • How does an entrainment nebulizer humidify inspired gas?
  • Where should you place an O2 analyzer to accurately assess FiO2?
  • Which statement explains why flow rate can be higher with a simple mask compared with a nasal cannula?
  • What issue can moisture cause NRB valves?
  • Which PaO2 range corresponds to mild hypoxemia?
  • What does a reservoir cannula do?
  • What FiO2 range can transtracheal catheters deliver?
  • Venti mask FiO2 at 2 LPM is which value?
  • Venti mask FiO2 at 12 LPM is which value?
  • During exhalation with a non-rebreather mask, which valve configuration is correct?
  • In LVN, temperature is maintained by which method?
  • If the oxygen flow to an NRB fails, what does the patient begin to breathe?
  • How does oxygen therapy correct hypoxemia?
  • Nasal cannula tips can be configured in which ways?
  • Which of the following is listed as an advantage of nasal prongs?
  • What design feature is referred to as 'star lumen' in nasal cannula tubing?
  • Jet nozzle size and entrainment relationship?
  • AEM stands for?
  • Which statement best describes high-flow oxygen therapy devices?
  • Which PaO2 range defines severe hypoxemia?
  • Which of the following is NOT an indication for transtracheal catheter?
  • In a large-volume nebulizer, which adjustment controls FiO2 by changing entrainment?
  • Which color corresponds to 6 LPM on a venti mask?
  • Anatomical reservoir in low flow oxygen therapy is best described as:
  • LVN is indicated when upper airways have been bypassed; example is which?
  • HFNC typically operates at what flow and relative humidity to be well tolerated?
  • In a T-piece, what is the purpose of the open end?
  • Low-flow oxygen devices are typically used for which purpose?
  • What is the function of the one-way valve on the non-rebreather mask?
  • What is the maximum flow level for comfort in nasal prongs?
  • What material are nasal cannula tubing made from?
  • In an infant incubator, what largely determines the FiO2 delivered?
  • What is the gas source for low-flow oxygen delivery devices?
  • What is a primary goal of oxygen therapy?
  • What FiO2 range is typical for a non-rebreather mask?
  • Which nebulizer is typically used for chronically ill patients to wean to a lower FiO2?
  • Venti mask FiO2 at 6 LPM is which value?
  • In a venti mask/LVN entrainment system, what happens to total flow as the oxygen flow increases?
  • Which device is the T-piece attached to?
  • What is the primary purpose of humidifying oxygen for patient delivery?
  • Is it advisable to connect entrainment devices to a humidifier unit?
  • What is considered normal PaO2 on room air with SpO2 typically 95-98%?
  • Where is a transtracheal catheter placed?
  • Which FiO2 value may be achieved at 8 LPM on a venti mask?
  • What is the approximate FiO2 with nasal prongs at 1 liter per minute?
  • What is a key limitation of non-rebreather masks?
  • What differentiates a non-rebreather mask from a simple partial rebreathing mask?
  • Which of the following is a venti mask part?
  • Which device uses soft plastic tubing less than 1 meter long with several small holes near the tip?
  • Which statement is an indication for transtracheal catheters?
  • Reservoir systems are designed to?
  • At a flow of 5–6 L/min, what approximate FiO2 does a simple mask provide?
  • What describes an anesthesia circuit in terms of reservoir systems?
  • What should the venti mask total flow be relative to the patient’s inspiratory demand?
  • Which term describes oxygen tension in arterial blood that is below normal?
  • Where is a transtracheal catheter placed?
  • What FiO2 range does the yellow top nebulizer produce, and what patient population is it typically used for?
  • Low flow devices have which characteristic?
  • Which description best explains how a partial rebreathing mask delivers oxygen?
  • What is true about entrainment devices when there is downstream back pressure?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy